top of page
760004267 | N-012-DS-8W-FSUYL/D

760004267 | N-012-DS-8W-FSUYL/D

TeraSPEED® Low Smoke Zero Halogen Riser Distribution Cable, 12 fiber single-unit, singlemode, yellow

  • Specification

    Product Classification

    Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
    Portfolio CommScope®
    Product Type Fiber indoor cable

    General Specifications

    Cable Type Distribution
    Construction Type Non-armored
    Fiber Type, quantity 12
    Jacket Color Yellow
    Subunit Type Gel-free
    Total Fiber Count 12

    Dimensions

    Diameter Over Jacket 6.07 mm | 0.239 in

     

    Mechanical Specifications

    Minimum Bend Radius, loaded 91 mm | 3.583 in
    Minimum Bend Radius, unloaded 61 mm | 2.402 in
    Tensile Load, long term, maximum 200 N | 44.962 lbf
    Tensile Load, short term, maximum 667 N | 149.948 lbf
    Compression 10 N/mm | 57.101 lb/in
    Compression Test Method FOTP-41 | IEC 60794-1 E3
    Flex 100 cycles
    Flex Test Method FOTP-104 | IEC 60794-1 E6
    Impact 5.88 N-m | 52.042 in lb
    Impact Test Method FOTP-25 | IEC 60794-1 E4
    Strain See long and short term tensile loads
    Strain Test Method FOTP-33 | IEC 60794-1 E1
    Twist 10 cycles
    Twist Test Method FOTP-85 | IEC 60794-1 E7
    Vertical Rise, maximum 500 m | 1640.42 ft

    Optical Specifications

    Fiber Type G.652.D and G.657.A1 , TeraSPEED® | G.652.D and G.657.A1, TeraSPEED®

    Environmental Specifications

    Installation temperature -10 °C to +60 °C (+14 °F to +140 °F)
    Operating Temperature -20 °C to +70 °C (-4 °F to +158 °F)
    Storage Temperature -40 °C to +70 °C (-40 °F to +158 °F)
    Cable Qualification Standards ANSI/ICEA S-83-596 | Telcordia GR-409
    EN50575 CPR Cable EuroClass Fire Performance Dca
    EN50575 CPR Cable EuroClass Smoke Rating s1a
    EN50575 CPR Cable EuroClass Droplets Rating d1
    EN50575 CPR Cable EuroClass Acidity Rating a2
    Environmental Space Low Smoke Zero Halogen (LSZH) | Riser
    Flame Test Listing NEC OFNR-LS (ETL) and c(ETL)
    Flame Test Method IEC 60332-3 | IEC 60754-2 | IEC 61034-2 | IEEE 383 | UL 1666 | UL 1685

    Environmental Test Specifications

    Heat Age -20 °C to +85 °C (-4 °F to +185 °F)
    Heat Age Test Method IEC 60794-1 F9
    Low High Bend -10 °C to +60 °C (+14 °F to +140 °F)
    Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
    Temperature Cycle -20 °C to +70 °C (-4 °F to +158 °F)
    Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1

    Packaging and Weights

    Cable weight 34 kg/km | 22.847 lb/kft

    Regulatory Compliance/Certifications

    Agency Classification
    CENELEC  EN 50575 compliant, Declaration of Performance (DoP) available
    ISO 9001:2015  Designed, manufactured and/or distributed under this quality management system
    ROHS Compliant
    CHINA-ROHS  Below maximum concentration value
    REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance

     