760004309 | N-072-DS-8W-FMUYL/C

760004309 | N-072-DS-8W-FMUYL/C

TeraSPEED® Low Smoke Zero Halogen Riser Distribution Cable, 72 fiber multi-unit with 12 fiber subunits

  • Specification

    Product Classification

    Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
    Portfolio CommScope®
    Product Type Fiber indoor cable

    General Specifications

    Cable Type Distribution
    Construction Type Non-armored
    Fiber Type, quantity 72
    Fibers per Subunit, quantity 12
    Jacket Color Yellow
    Subunit Type Gel-free
    Subunit, quantity 6
    Total Fiber Count 72

    Dimensions

    Buffer Tube/Subunit Diameter 6.07 mm | 0.239 in
    Diameter Over Jacket 20.01 mm | 0.788 in

    Mechanical Specifications

    Minimum Bend Radius, loaded 300 mm | 11.811 in
    Minimum Bend Radius, unloaded 200 mm | 7.874 in
    Tensile Load, long term, maximum 400 N | 89.924 lbf
    Tensile Load, short term, maximum 1335 N | 300.12 lbf
    Compression 10 N/mm | 57.101 lb/in
    Compression Test Method FOTP-41 | IEC 60794-1 E3
    Flex 100 cycles
    Flex Test Method FOTP-104 | IEC 60794-1 E6
    Impact 5.88 N-m | 52.042 in lb
    Impact Test Method FOTP-25 | IEC 60794-1 E4
    Strain See long and short term tensile loads
    Strain Test Method FOTP-33 | IEC 60794-1 E1
    Twist 10 cycles
    Twist Test Method FOTP-85 | IEC 60794-1 E7
    Vertical Rise, maximum 113 m | 370.735 ft

    Optical Specifications

    Fiber Type G.652.D and G.657.A1 , TeraSPEED® | G.652.D and G.657.A1, TeraSPEED®

    Environmental Specifications

    Installation temperature -10 °C to +60 °C (+14 °F to +140 °F)
    Operating Temperature -20 °C to +70 °C (-4 °F to +158 °F)
    Storage Temperature -40 °C to +70 °C (-40 °F to +158 °F)
    Cable Qualification Standards ANSI/ICEA S-83-596 | Telcordia GR-409
    EN50575 CPR Cable EuroClass Fire Performance Cca
    EN50575 CPR Cable EuroClass Smoke Rating s1b
    EN50575 CPR Cable EuroClass Droplets Rating d1
    EN50575 CPR Cable EuroClass Acidity Rating a1
    Environmental Space Low Smoke Zero Halogen (LSZH) | Riser
    Flame Test Listing NEC OFNR-LS (ETL) and c(ETL)
    Flame Test Method IEC 60332-3 | IEC 60754-2 | IEC 61034-2 | IEEE 383 | UL 1666 | UL 1685

    Environmental Test Specifications

    Heat Age -20 °C to +85 °C (-4 °F to +185 °F)
    Heat Age Test Method IEC 60794-1 F9
    Low High Bend -10 °C to +60 °C (+14 °F to +140 °F)
    Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
    Temperature Cycle -20 °C to +70 °C (-4 °F to +158 °F)
    Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1

    Packaging and Weights

    Cable weight 360 kg/km | 241.909 lb/kft

    Regulatory Compliance/Certifications