top of page
760229740 | R-012-DS-5G-FSULM

760229740 | R-012-DS-5G-FSULM

 

LazrSPEED® Riser Distribution Cable, 12 fiber single-unit

  • Specification

    Product Classification

    Regional Availability Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America
    Portfolio CommScope®
    Product Type Fiber indoor cable

    General Specifications

    Cable Type Distribution
    Construction Type Non-armored
    Fiber Type, quantity 12
    Jacket Color Lime green
    Subunit Type Gel-free
    Total Fiber Count 12

    Dimensions

    Diameter Over Jacket 5.95 mm | 0.234 in

    Mechanical Specifications

    Minimum Bend Radius, loaded 89 mm | 3.504 in
    Minimum Bend Radius, unloaded 59 mm | 2.323 in
    Tensile Load, long term, maximum 200 N | 44.962 lbf
    Tensile Load, short term, maximum 667 N | 149.948 lbf
    Compression 10 N/mm | 57.101 lb/in
    Compression Test Method FOTP-41 | IEC 60794-1 E3
    Flex 100 cycles
    Flex Test Method FOTP-104 | IEC 60794-1 E6
    Impact 5.88 N-m | 52.042 in lb
    Impact Test Method FOTP-25 | IEC 60794-1 E4
    Strain See long and short term tensile loads
    Strain Test Method FOTP-33 | IEC 60794-1 E1
    Twist 10 cycles
    Twist Test Method FOTP-85 | IEC 60794-1 E7
    Vertical Rise, maximum 500 m | 1640.42 ft

    Optical Specifications

    Fiber Type OM5, LazrSPEED® wideband | OM5, LazrSPEED® wideband

    Environmental Specifications

    Installation temperature -20 °C to +70 °C (-4 °F to +158 °F)
    Operating Temperature -20 °C to +70 °C (-4 °F to +158 °F)
    Storage Temperature -40 °C to +70 °C (-40 °F to +158 °F)
    Cable Qualification Standards ANSI/ICEA S-83-596 | Telcordia GR-409
    Environmental Space Riser
    Flame Test Listing NEC OFNR (ETL) and c(ETL)
    Flame Test Method UL 1666

    Environmental Test Specifications

    Heat Age -20 °C to +85 °C (-4 °F to +185 °F)
    Heat Age Test Method IEC 60794-1 F9
    Low High Bend -20 °C to +70 °C (-4 °F to +158 °F)
    Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
    Temperature Cycle -20 °C to +70 °C (-4 °F to +158 °F)
    Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1

    Packaging and Weights

    Cable weight 32 kg/km | 21.503 lb/kft

    Regulatory Compliance/Certifications

    Agency Classification
    ISO 9001:2015  Designed, manufactured and/or distributed under this quality management system

     